佳工机电网 在线工博会 我的佳工网 手机版 English
关键字  
  选择展区 >>
您的位置: 首页 > 仪器/仪表/衡器展区 > 实验室仪器展厅 > 新闻 > 正文 产品 会展 人才 帮助 | 注册 登录  
实验室仪器
 按行业筛选
 按产品筛选
本产品全部新闻


e展厅 产品库 视频 新闻 技术文章 企业库 下载/样本 求购/论坛
  市场动态 | 技术动态 | 企业新闻 | 图片新闻 | 新闻评论 佳工网行业新闻--给您更宽的视角 发表企业新闻 投稿 
Measuring The Density Of Ultra-pure Water
http://cn.newmaker.com 12/26/2007 12:12:00 PM  佳工机电网
Measuring The Density Of Ultra-pure WaterView of the magnetic flotation equipment. The sinker lies on a holder whose weight is compensated by the buoyancy of a hollow sphere and of an adjusting weight. (Credit: Image courtesy of Physikalisch-Technische Bundesanstalt)

ScienceDaily (Dec. 24, 2007) — For oceanography - and there in particular for the description of ocean currents - accurate measurements of the density of sea water are of great importance. For this purpose, measuring instruments are needed which reach an uncertainty of approx. 0.001 kg/m3 (relative 1 · 10-6). To be able to calibrate these measuring instruments, ultra-pure water is required as a reference fluid - the density of which can now be measured with the required accuracy over a large temperature range by means of the Magnetic Flotation Method which has been further developed at PTB.

Normally, the hydrostatic weighing method is used for measuring the density of liquids. Thereby, the density of the liquid is determined by means of Archimedes' principle from the buoyancy which is experienced by a sinker that plunges into the fluid. This method has several disadvantages which become apparent especially when water is to be measured. For this method, an open fluid tank is required into which the sinker - hanging on a wire - plunges.


At the point where the wire passes through the surface of the liquid into the water, a meniscus forms which, in the case of water, is extremely difficult to be reproduced and therefore contributes significantly to the measurement uncertainty. Along the wire, a temperature gradient occurs which, too, increases the measurement uncertainty. Due to the open system, the gas content of the water is difficult to control, but it alters the density.

In order to eliminate these sources of uncertainty, an apparatus has been developed in which the wire has been replaced by a magnetic coupling. In this magnetic flotation system, a small magnet is mounted at the holder of the sinker. By means of this magnet, and with the aid of a controllable magnetic field produced by an electromagnet, the sinker is kept in a fixed position. The current needed for this purpose is a measure for the buoyancy that is experienced by the sinker.


The fluid tank can almost be shut as the liquid is linked with the outside world only via a thin pipe by means of which the pressure can be regulated. In this way, it is possible to measure also with fully degassed water.

Thanks to the fact that the above-mentioned sources of uncertainty are avoided, measurements can be carried out with a repeatability standard deviation of approx. 2 · 10-7. The total measurement uncertainty of the water density measurement therefore reaches a value below 1 · 10-6.


The measurements carried out with this new apparatus could confirm to a large extent the values delivered by foreign colleagues. However, there are still discrepancies in the temperature range around 4 °C, which is of great importance especially in oceanography. Therefore, there is still a great need for further research in this field.

Adapted from materials provided by Physikalisch-Technische Bundesanstalt.

欢迎访问e展厅
展厅
2
实验室仪器展厅
天平, 振动研磨机, 移液器, 生命科学仪器, 摇床, ...


发表评论】【新闻评论】【论坛】【收藏此页
更多有关实验室仪器的新闻:
·美开发出利用激光分离细胞新系统 12/21/2007
·国产商用电波钟分秒不差 打破发达国家技术垄断 12/20/2007
·我国首个高能大功率辐照加速器示范工程建成 12/19/2007
·[图]中科院固体所制备出可调光氧化铝薄膜 11/20/2007
·BFEL单脉冲最高输出能量超过8mJ 10/29/2007
·安捷伦研讨会力推纳米技术与测量方案 3/12/2007
·[图]中国研制成功世界首台角分辨光电子能谱仪 2/8/2007
·首台研究材料内部精细结构的科学仪器 1/5/2007
·哈工大研制出便携式多波束测深仪 11/23/2006
·我国将建40万高斯强磁场实验室 11/2/2006
查看与本新闻相关目录:
·仪器/仪表/衡器展区 > 实验室仪器展厅 > 实验室仪器技术动态

对 实验室仪器 有何见解?请到
实验室仪器论坛 畅所欲言吧!





网站简介 | 企业会员服务 | 广告服务 | 服务条款 | English | Showsbee | 会员登录  
© 1999-2024 newmaker.com. 佳工机电网·嘉工科技