Faster X-ray Interferometers Due To Single-photon Interference
http://cn.newmaker.com 12/24/2007 4:15:00 PM  佳工机电网
Faster X-ray Interferometers Due To Single-photon InterferenceThe core piece of the X-ray interferometer, made from a silicon single crystal, furnishes the lattice parameter of silicon as an utmost precisely determined length scale. (Credit: Image courtesy of Physikalisch-Technische Bundesanstalt)

ScienceDaily (Dec. 21, 2007) — By means of X-ray interferometers, lengths down to the mm range can be measured with a resolution of less than one nm. The low translation velocity of the interferometers, which made their use in practice more difficult, could now be increased by a factor of 100 by exploiting the temporal correlation of singly interfering X-ray photons.

X-ray interferometers can measure lengths in the mm range with sub-nm resolution, whereby the almost perfect crystal grid of high-purity silicon is used as a length scale. The dimensions of any sub-µm-structured samples are thereby compared with the lattice parameter of silicon (λ0~0.543... nm) which has been determined very precisely within the scope of the project for the new definition of the Avogadro constant. For metrological applications in connection with scanning probe microscopes, such measurements are of great importance.

Up to now, a further spreading of this method had, however, been impeded by the low translation velocities of only 1 nm/s to 10 nm/s. They are due to the limited intensity of typical laboratory X-ray sources: the necessary filtering of the periodic interference signal leads to a reduction in contrast which, in a classic measurement, requires a slow translation of the interferometer.

In a quantum-mechanical sense, however, interference occurs also in a strongly "diluted" stream of X-ray photons: Regarded as a wave packet, even single photons follow in their temporal impact on the detector the same probability which, in the case of sufficiently intense X-ray light, leads to the continuous signal whose period one wants to determine.


This well-known quantum-mechanical fact is now exploited for a specific purpose: if one protocols the times at which the single photons hit the detector, one can, by means of a subsequent Fourier transform of this time series, determine very precisely the frequency at which the lattice periods were passed. At constant velocity, it is then possible to reconstruct the path information, and one obtains the same information as with the classic measurement, but in a much shorter amount of time.

Thus, translation velocities of up to 1000 nm/s could be realised. This method will in future not only be used in further improved measuring arrangements for the determination of the lattice parameter of silicon, but also for other length measurements in nanotechnology.

Adapted from materials provided by Physikalisch-Technische Bundesanstalt.

欢迎访问e展厅
展厅
4
光学仪器展厅
显微镜, 金相显微镜, CCD摄像机, 水准仪, 光谱仪, ...


发表评论】【新闻评论】【论坛】【收藏此页
更多有关光学仪器的新闻:
·[图]埃赛力达推出用于荧光显微镜的X-Cite XYLIS II广谱LED照明系统 11/28/2023
·[图]Excelitas公司推出µPAX-3脉冲氙气光源 适用于分析仪器应用的新款小型、精确对准的2W光源 1/5/2022
·[图]埃赛力达科技推出含自动对焦功能的Qioptiq® mag.x system 125新型光学系统 11/11/2020
·[图]Qioptiq推出F-Theta-Ronar 160mm透镜 提供高精度且光斑尺寸小的短焦距 3/13/2019
·[图]埃赛力达推出波长为515-540nm的F-Theta Ronar 420mm透镜 3/13/2019
·[图]AGV-SPO 高性能单轴点扫描振镜 2/21/2019
·上海光谱自吸背景校正原子吸收光谱仪通过鉴定 12/21/2007
·“天眼”相助非法开采将无处遁形 12/8/2007
·[图]尼康上市支持半间距40nm工艺的自动宏观检查装置 12/6/2007
·[图]XL-80轻巧型激光干涉仪测量系统 11/28/2007
查看与本新闻相关目录:
·仪器/仪表/衡器展区 > 光学仪器展厅 > 光学仪器技术动态

对 光学仪器 有何见解?请到
光学仪器论坛 畅所欲言吧!





网站简介 | 企业会员服务 | 广告服务 | 服务条款 | English | Showsbee | 会员登录  
© 1999-2024 newmaker.com. 佳工机电网·嘉工科技